QuickOPC Compatibility Test List: Difference between revisions

From OPC Labs Knowledge Base
(outline)
 
 
(191 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[Category:Application note]]
[[Category:Application note]] [[Category:Compatibility]] [[Category:macOS]] [[Category:OPC UA File Transfer]] [[Category:Raspberry Pi]] [[Category:Raspberry Pi OS]]  
Older test lists: [[Application note: QuickOPC-UA Compatibility Test List]]
Older test lists: [[Application note: QuickOPC-UA Compatibility Test List]]


See also: [[QuickOPC Compatibility Test List for PubSub]]
== Introduction ==
== Introduction ==


=== Field descriptions ===
See [[Compatibility Test Lists - Concepts]].


==== Other system model ====
== Platform Hardware ==


==== Other system version ====
{| class="wikitable"
|+
!Other system model
!Other system version
!Test date
!Performed by
!This product version
!Test type
!Test outcome
!Notes


==== Test date ====
|-
|'''PC, Intel Core2 Quad CPU  Q6600 @ 2.40 GHz  2.39 GHz; 4.00 GB'''
|
|2018-06
|OPC Labs
|2018.2 (5.53)
|Basic test
|<span style='color:green'>Passed</span>
|W7SP1/x32


==== Performed by ====
|-
|rowspan="3"|'''PC, Intel Core i7-3930K CPU @ 3.20 GHz  3.80 GHz; 32.0 GB'''
|
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|W7SP1/x64


==== This product version ====
|-
|
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:green'>Passed</span>
|W7SP1/x64


==== Test type ====
|-
|
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|W7SP1/x64


==== Test outcome ====
|-
|'''PC, Intel Core i7-7820X CPU @ 3.60 GHz  3.60 GHz; 32.0 GB'''
|
|2018-06
|OPC Labs
|2018.3 (5.54)
|Developer test
|<span style='color:green'>Passed</span>
|W10/x64


==== Notes ====
|-
|rowspan="2"|'''PC, Intel Core i7-8550U CPU @ 1.80 GHz  1.99 GHz; 16.0 GB'''
|
|2019-03
|OPC Labs
|2019.1 (5.55)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|W10/x64


== Platform hardware ==
|-
|
|2023-03
|OPC Labs
|2023.1 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|W10/x64


== Operating systems ==
|-
|'''Raspberry Pi Model 4; 4 GB'''
|
|2021-01
|OPC Labs
|2021.1 (5.60)
|Basic test
|<span style='color:green'>Passed</span>
|Raspbery Pi OS
|}


== OPC servers ==
More tests were performed, currently not explicitly listed here.
 
== Operating Systems ==
 
{| class="wikitable"
|+
!Other system model
!Other system version
!Test date
!Performed by
!This product version
!Test type
!Test outcome
!Notes
 
|-
|'''CentOS'''
|7.5.1804
|2018-07
|OPC Labs
|2018.3 (5.54)
|Basic test
|<span style='color:green'>Passed</span>
|RID: centos.7-x64
 
|-
|'''macOS High Sierra'''
|10.13.6
|2021-02
|OPC Labs
|2021.1 (5.60)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="4"|'''Microsoft Windows 7 Enterprise'''
|SP1, x64 (English)
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|SP1, x32 (English)
|2018-06
|OPC Labs
|2018.2 (5.53)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|SP1, x64 (English)
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|SP1, x64 (English)
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="5"|'''Microsoft Windows 10 Pro'''
|1803, x64 (English)
|2018-06
|OPC Labs
|2018.3 (5.54)
|Developer test
|<span style='color:green'>Passed</span>
|RID: win10-x64
 
|-
|1803, x64 (English)
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|1903, x64 (English)
|2019-08
|OPC Labs
|2019.1 (5.55.0.12)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|1903, x86 (English)
|2019-08
|OPC Labs
|2019.1 (5.55.0.12)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|22H2, x64 (English)
|2023-03
|OPC Labs
|2023.1 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Microsoft Windows Server 2019 Datacenter'''
|1809 (Aug 2019), x64 (English)
|2019-08
|OPC Labs
|2019.1 (5.55.0.12)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Oracle Linux'''
|7.5
|2018-07
|OPC Labs
|2018.3 (5.54)
|Basic test
|<span style='color:green'>Passed</span>
|RID: linux-x64
 
|-
|'''Raspberry Pi OS with desktop'''
|2021-01-11
|2021-01
|OPC Labs
|2021.1 (5.60)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Red Hat Enterprise Linux'''
|7.4
|2018-06
|OPC Labs
|2018.3 (5.54)
|Basic test
|<span style='color:green'>Passed</span>
|RID: rhel.7-x64
 
|-
|rowspan="2"|'''Ubuntu'''
|17.10
|2018-06
|OPC Labs
|2018.3 (5.54)
|Basic test
|<span style='color:green'>Passed</span>
|RID: linux-x64
 
|-
|18.04
|2018-06
|OPC Labs
|2018.3 (5.54)
|Basic test
|<span style='color:green'>Passed</span>
|RID: ubuntu.18.04-x64
|}
 
More tests were performed, currently not explicitly listed here.
 
== .NET Runtimes ==
 
{| class="wikitable"
|+
!Other system model
!Other system version
!Test date
!Performed by
!This product version
!Test type
!Test outcome
!Notes
 
|-
|rowspan="3"|'''.NET'''
|5.0.2
|2021-01
|OPC Labs
|2021.1 (5.60.0.13)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|6.0.6
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|8.0.1
|2024-03
|OPC Labs
|2024.2 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="7"|'''.NET Core'''
|2.0.6
|2018-06
|OPC Labs
|2018.3 (5.54)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|2.0.7
|2018-06
|OPC Labs
|2018.3 (5.54)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|2.1.2
|2018-07
|OPC Labs
|2018.3 (5.54)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|2.1.6
|2019-07
|OPC Labs
|2019.1 (5.55.0.3)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|2.1.12
|2019-08
|OPC Labs
|2019.1 (5.55.0.12)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|2.1.24
|2021-01
|OPC Labs
|2021.1 (5.60.0.13)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|3.1.11
|2021-01
|OPC Labs
|2021.1 (5.60.0.13)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="4"|'''.NET Framework'''
|4.7
|2019-08
|OPC Labs
|2019.1 (5.55.0.12)
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|4.7.2
|2022-10
|OPC Labs
|2022.1 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|4.7.2
|2023-03
|OPC Labs
|2023.1 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|4.8
|2019-08
|OPC Labs
|2019.1 (5.55.0.12)
|Basic test
|<span style='color:green'>Passed</span>
|
|}
 
More tests were performed, currently not explicitly listed here.
 
== OPC Servers ==
 
=== OPC UA Generic/Data ===
 
{| class="wikitable"
|+
!Other system model
!Other system version
!Test date
!Performed by
!This product version
!Test type
!Test outcome
!Notes
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- 3 -
 
|-
|rowspan="3"|'''3S-Smart Software Solutions: CODESYS OPC UA Server'''
|
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|V3.5.13.10
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|3.5.19.0
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- B -
 
|-
|'''Baker Hughes/GE: iFIX'''
|6.0
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Beckhoff Automation: TF6100 OPC-UA'''
|2.2.21
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="2"|'''Beckhoff Automation: TwinCAT TF6100 OPC UA (Client/Server)'''
|3.x
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|4.0
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Bosch Rexroth: IndraMotion MTX'''
|14VRS
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-unknown-https-endpoint">do not know the HTTPS endpoint</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- C -
 
|-
|'''Certec EDV: atvise'''
|3.3.0
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- D -
 
|-
|'''dieEntwickler Elektronik: SITOP PSU8600'''
|1.2.0-Dev
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:red'>Failed</span>
|<ref name="opc-servers-BadIdentityTokenRejected">getting BadIdentityTokenRejected from ActivateSession() with user identity = username/password</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- E -
 
|-
|'''Enapter GmbH: Enapter UA Server'''
|1.00
|2024-03
|OPC Labs
|2024.2 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- F -
 
|-
|'''Fraunhofer-Gesellschaft: IOSB AAS OPC UA Server'''
|0.3
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Fraunhofer-Gesellschaft: open62541 TestServer'''
|1.3
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Fraunhofer-Gesellschaft: ProVis.Agent'''
|2.15.14
|2019-07
|OPC Labs
|2019.1 (5.55.0.3)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Fraunhofer-Gesellschaft: SecurePlugAndWorkUAServer'''
|1.1.3
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- G -
 
|-
|'''General Electric Corporation: CIMPLICITY OPC UA Server'''
|9.5 Beta
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-servers-SessionDiagnosticsArray-credentials">the ServerDiagnostics.SessionDiagnosticsArray cannot be read with the credentials provided for testing</ref>
 
|-
|'''General Electric Corporation: CIMPLICITY Server'''
|9.5 SIM2
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-publish-interval-revised-to-0">server is revising publishing intervals to 0 and using its own</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- H -
 
|-
|'''Hilscher: netFIELD IoLinkMaster 8 Port'''
|V1.2.2.0
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Hilscher: OPC UA Server Micro'''
|0.9.11.1
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-IndexRange">failed: reading and writing with IndexRange</ref>
 
|-
|'''Hilscher: OPC UA Server Nano'''
|0.9.11.1
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-IndexRange">failed: reading and writing with IndexRange</ref>
 
|-
|'''HIMA Paul Hildebrandt: HIMA OPCUA Server'''
|1.0
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-nodynamics">No dynamic nodes could have been tested.</ref>
 
|-
|'''HMS Industrial Networks: eWON Flexy FW'''
|13.1PR
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Honeywell: ControlEdge PLC'''
|R152
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Honeywell: Experion PKS OPC UA DA/HDA Server'''
|
|2020-03
|OPC Labs
|2020.2 (5.58.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref>Empty ArrayDimensions instead of null returned with ValueRank=-2.</ref><ref>DataChangeFilter=StatusValue does not prevent constant value with updating timestamps from being sent.</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- I -
 
|-
|'''IBHsoftec: IBH Link UA'''
|3.07
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green>Passed</span>
|<ref name="opc-servers-SessionDiagnosticsArray-objects">The SessionDiagnosticsArray node is missing, but the sessions are correctly available under SessionDiagnosticsSummary.</ref>
 
|-
|'''IBHsoftec: IBH OPC UA IOT2040'''
|3.07
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green>Passed</span>
|<ref name="opc-servers-SessionDiagnosticsArray-objects"/>
 
|-
|'''ICONICS: GENESIS64'''
|10.96
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>Server sends data changes too fast.</ref><ref name="opc-servers-absolute-deadband-violation"/>
 
|-
|rowspan="3|'''Inductive Automation: Eclipse Milo OPC-UA Server SDK'''
|0.1.0-SNAPSHOT
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-servers-https-may-not-be-supported">HTTPS not supported by the server?</ref>
 
|-
|0.3.0-SNAPSHOT
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|1.0.0-SNAPSHOT
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="2"|'''Inductive Automation: Ignition OPC-UA Server'''
|8.0
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|8.1.21-SNAPSHOT
|2022-10
|OPC Labs
|2022.1 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''inray Industriesoftware GmbH: OPC Router 4'''
|4.27.5018.76
|2022-10
|OPC Labs
|2022.1 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''IPCOMM: ipConvLite'''
|3.x
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''IPCOMM: ipConvOPC'''
|3.x
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- K -
 
|-
|'''Kepware Technologies: Kepware Edge'''<ref>Linux; driver-based</ref>
|Beta 6.7
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Kepware Technologies: OPC UA Server - KEPServerEX'''
|6.0
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- M -
 
|-
|'''MatrikonOPC: FLEX OPC UA SDK - Embedded Server Profile'''
|R410.3
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''MatrikonOPC: FLEX OPC UA SDK - Micro Embedded Device Server Profile'''
|R410.3
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''MatrikonOPC: FLEX OPC UA SDK - Nano Embedded Device Server Profile'''
|R410.2
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''MatrikonOPC: FLEX OPC UA SDK - Standard Server Profile'''
|R410.3
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Microsoft: .Net Standard Library OPC Server'''
|Nov-11-2016
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-SessionDiagnosticsArray">reading Server_ServerDiagnostics_SessionsDiagnosticsSummary_SessionDiagnosticsArray (nsu=http://opcfoundation.org/UA/;i=3707) gives BadOutOfService</ref>
 
|-
|'''Microsoft: .Net Standard Reference Server (Ubuntu)'''
|Sep-18-2017
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Microsoft: .Net Standard Reference Server (Windows)'''
|1.4.371.xx
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Microsoft: .Net Standard GDS Server'''
|Sep-18-2017
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- O -
 
|-
|'''OMRON: NJ OPC UA Server'''
|
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-servers-SessionDiagnosticsArray-objects"/>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- P -
 
|-
|'''Phoenix Contact: PC WORX UA Server'''
|1.03.961.3
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-SessionDiagnosticsArray-BadNodeIdUnknown">reading ServerDiagnostics.SessionDiagnosticsArray gives BadNodeIdUnknown</ref>
 
|-
|'''Progea: Platform.NExT'''
|3.3.200
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Progea: Connext '''
|3.3.200
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Prosys OPC: OPC UA Java SDK'''
|
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>All nodes (even scalars from standard information model etc.) have ValueRank equal to -2 (Any): not compliant.</ref>
 
|-
|'''Prosys OPC: Sentrol - OPC UA SDK for Delphi'''
|7.0 Beta
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:red'>Failed</span>
|<ref>The server returns ValuRank 0 for scalar nodes.</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- R -
 
|-
|'''Real Time Automation: Royalty-Free ANSI C OPC UA Server Stack, Toolkit & SDK'''
|1.0
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Rockwell Automation: FactoryTalkLinxGateway'''
|6.10
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>GetEndpoints can return overloaded set of endpoints</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- S -
 
|-
|'''SAP SE: Plant Connectivity on Linux (Raspbian)'''
|15.1.5
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-servers-methods-only">Could not test much, server only has method calls support.</ref>
 
|-
|'''SAP SE: Plant Connectivity on Windows 10'''
|15.1.5
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-servers-methods-only"/>
 
|-
|'''Schneider Electric: InduSoft IoTView OPC UA Server (Linux)'''
|v8.1 SP3
|2018-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Schneider Electric: Indusoft Web Studio OPC UA Server'''
|v8.1 SP3
|2018-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Schneider Electric: M262'''
|(n/a)
|2024-03
|OPC Labs
|2024.2 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Siemens: miniweb OPC UA'''
|5.3.2 beta
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:red'>Failed</span>
|<ref>1) Effects of Writes with IndexRange are not sent through subscription. 2) Subscription ignores IndexRange. 3) After writing into an IndexRange, the whole array seems to be replaced when doing subsequent Read</ref>
 
|-
|'''Siemens: SIMATIC CPU 1516-3 PN/DP'''
|V2.6
|2019-07
|OPC Labs
|2019.1 (5.55.0.3)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref>Sampling period 2000 ms, but receiving changes at around 1000 ms rate.</ref>
 
|-
|'''Siemens: SIMATIC NET OPC Server S7 opt'''
|V13 SP1
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-sends-changes-too-fast">Server sends changes too fast. I used sampling interval 2000 ms. The server has not revised it. But it has been sending notifications with average rate between 800-900 ms. I think it would be OK to send values faster than requested, but in that case the server should report the faster revised sampling rate properly to the client.</ref>
 
|-
|'''Siemens: SIMATIC RF100'''
|V1.1
|2019-07
|OPC Labs
|2019.1 (5.55.0.3)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>Reading ArrayDimensions gives an array with zero elements. NodeID: ns=4;i=6013</ref>
 
|-
|'''Siemens: SIMATIC RF600'''
|V3.1
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Siemens: SIMATIC S7-1500'''<ref name="opc-servers-homer">for S7-1500 family</ref>
|V3.0
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Siemens: SIMATIC S7-1518'''<ref name="opc-servers-homer">for S7-1500 family</ref>
|V2.5
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="3"|'''Siemens: Simatic WinCC'''
|V7.4
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-servers-no-arrays">no arrays available for testing</ref>
 
|-
|V7.5
|2018-10
|OPC Labs
|5.54 (2018.3.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-servers-no-arrays">no arrays available for testing</ref>
 
|-
|V8.0
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Siemens: WinCC Runtime Professional'''
|V15.1
|2018-10
|OPC Labs
|5.54 (2018.3.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Softing Industrial Automation: dataFEED OPC SIS'''
|1.12
|2019-07
|OPC Labs
|2019.1 (5.55.0.3)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="2"|'''Softing Industrial Automation: dataFEED OPC Suite'''
|4.43.0
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>sometimes getting just BadWaitingForInitialData and no further update</ref>
 
|-
|5.22.0
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Softing Industrial Automation: dataFEED OPC UA .NET Standard Server SDK'''
|2.2
|2019-07
|OPC Labs
|2019.1 (5.55.0.3)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Softing Industrial Automation: edgeAggregator'''
|3.10
|2022-10
|OPC Labs
|2022.2 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Softing Industrial Automation: Falcon Server'''<ref name="opc-servers-softing-falcon">Falcon appears to be a code name for upcoming version of dataFEED OPC Suite.</ref>
|
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-falcon-https">Getting "Could not create SSL/TLS secure channel." with HTTPS endpoint; it is possible that the problem is on the client side.</ref>
 
|-
|'''Softing Industrial Automation: OPC UA C++ Server Development Toolkits for Windows'''
|1.00
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Softing Industrial Automation: OPC UA Embedded Toolkit'''
|5.53
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Softing Industrial Automation: OPC UA .NET Server Development Toolkits'''
|1.43
|2017-09
|OPC Labs
|2017.2 (5.51.0.7)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>Writing with index range always gives BadIndexRangeInvalid</ref><ref name="opc-servers-absolute-deadband-violation"/>
 
|-
|rowspan="2"|'''Sterfive SAS node-opcua sdk'''
|2.27
|2021-04
|OPC Labs
|2021.2 (5.61.0.6)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>Getting BadSecurityChecksFailed with attempts to make any secure connection.</ref><ref>Null in StructureField.DataType (AutoID ScanData) instead of BaseDataType.</ref>
 
|-
|
|2022-10
|OPC Labs
|2022.2 Alpha
|Basic test
|<span style='color:green'>Passed</span>
|
 
|-
|'''Systerel: S2OPC Demo Server'''
|0.5.0*
|2018-10
|OPC Labs
|5.54 (2018.3.0.33)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>There are nodes that have variable class, but return BadAttributeInvalid for the UserAccessLevel and Historizing attributes, which are mandatory.</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- T -
 
|-
|'''Takebishi: Device Gateway'''
|2.1.2
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Takebishi: DeviceXPlorer OPC Server'''
|6.0 Pre
|2018-10
|OPC Labs
|2019.1 (5.55.0.3)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref>When the publishing rate was 1000 ms and sampling rate 2000 ms, the server provides changes every 1000 ms, which means it is sampling faster than requested.</ref><ref>On subsequent connections after a network interruption, no initial update was sent for items that are static.</ref>
 
|-
|'''Tani: OPC Server'''
|1.7
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Tani: OPC Server Linux'''
|1.7
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="opc-servers-values-not-changing">values not changing</ref>
 
|-
|'''Tani: PLC Engine Server raspberry'''
|1.12
|2016-11
|OPC Labs
|5.41
|Interoperability workshop
|<span style='color:red'>Failed</span>
|<ref name="opc-servers-BadIdentityTokenRejected"></ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- U -
 
|-
|'''Unified Automation: .NET based OPC UA Server SDK'''
|2.4.0
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-lds-not-running"/><ref name="opc-servers-absolute-deadband-violation">Absolute Deadband filter: server sometimes sends notifications where the difference is less than the deadband</ref>
 
|-
|'''Unified Automation: C based OPC UA Server SDK'''
|1.5.1
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-lds-not-running">looks like LDS is not running</ref>
 
|-
|'''Unified Automation: C++ based OPC UA Server SDK WINDOWS'''
|1.5.0
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="opc-servers-lds-not-running"/>
 
|-
|'''Unified Automation: High Performance OPC UA SDK'''
|1.3.0 BETA
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Unified Automation: UA Gateway - connect classic OPC'''<ref>based on Unified Automation C++ SDK</ref>
|1.5.0
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''University of West Bohemia in Pilsen: OPC UA server for REX Control System'''
|1.0.0
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- V -
 
|-
|'''VDMA Weighing Demo Server'''
|as of test date
|2021-10
|OPC Labs
|2021.3 Alpha
|Targeted test
|<span style='color:green'>Passed</span>
|<ref>Reading weight structures, such as nsu=http://yourorganisation.org/isw_personwaage/ ;ns=4;i=6001 .</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- W -
 
|-
|'''WAGO Kontakttechnik: Controllers PFC100 & PFC200'''
|0750-8212
|2021-10
|OPC Labs
|2021.3 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref>Structure fields that are multi-dimensional arrays are encoded incorrectly: The array of actual dimensions is missing, and instead, just the total number of elements is encoded, as if the array was one-dimensional.</ref><ref>StructureField.maxStringLength is in characters and not in UTF-8 encoded bytes.</ref>
 
|-
|colspan="8" style="font-weight:bold;color:blue"|- Y -
 
|-
|'''Yokogawa Electric Corporation: FAST/TOOLS OPC UA Server'''
|R10.04 SP1
|2019-07
|OPC Labs
|2019.1 (5.55.0.3)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref>Buggy NodeClassMask filtering in Browse service.</ref>
 
|-
|'''Yokogawa Electric Corporation: MDIS Demo Server'''
|
|2020-03
|OPC Labs
|2020.2 (5.58.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref>Sample delivery approx. 50% slower than requested.</ref>
 
|-
|'''Yokogawa Electric Corporation: opaf demo server'''
|
|2019-03
|OPC Labs
|2019.1 (5.55.0.2)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Yokogawa Electric Corporation: UA Server for CENTUM VP'''
|R1.02.10
|2015-11
|OPC Labs
|5.36
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|}
 
=== OPC UA Global Discovery Services (GDS), Certificate Management (CM) ===
 
{| class="wikitable"
|+
!Other system model
!Other system version
!Test date
!Performed by
!This product version
!Test type
!Test outcome
!Notes
 
|-
|'''Microsoft: .Net Standard GDS server'''
|1.5.374
|2024-03
|OPC Labs
|2024.2 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''Microsoft: Azure IoT OPC Vault GDS Server'''
|private preview
|2018-10
|OPC Labs
|2018.3 (5.54.0.33)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
 
|-
|'''OPC Foundation: UA .Net Standard Global Discovery Server'''
|1.03.352.12
|2018-09
|OPC Labs
|2018.3 (5.54.0.33)
|Developer Test
|<span style='color:green'>Passed</span>
|
 
|-
|rowspan="2"|'''Unified Automation: UA GDS'''
|as of test date
|2021-10
|OPC Labs
|2021.3 Alpha
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="nopfxformat">PFX format not supported (only PEM) in StartNewKeyPairRequest. Consequently, QuickOPC needs to target .NET Standard so that it can use StartSigningRequest instead.</ref>
 
|-
|as of test date
|2023-03
|OPC Labs
|2023.1 Alpha
|Interoperability workshop
|<span style='color:green'>Passed</span>
|
|}
 
=== OPC UA File Transfer ===
 
{| class="wikitable"
|+
!Other system model
!Other system version
!Test date
!Performed by
!This product version
!Test type
!Test outcome
!Notes
 
|-
|'''Fraunhofer-Gesellschaft: Fraunhofer IOSB AAS OPC UA Server'''
|0.5
|2021-04
|OPC Labs
|2021.2 (5.61.0.6)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="filetypeonly">Only isolated files available for test (no directores/file system).</ref><ref>File writing was not available for test.</ref>
 
|-
|'''Hilscher: netFIELD IoLinkMaster 8 Port'''
|V1.1.7.0
|2021-04
|OPC Labs
|2021.2 (5.61.0.6)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="nofiletypegetposition">GetPosition method of FileType does not work.</ref><ref name="nofiletypechunks">File must be written using a single call to the Write method on FileType (no chunking possible).</ref>
 
|-
|'''Hilscher: netFIELD DIOConnector 8 DIO Port'''
|V1.1.7.0
|2021-04
|OPC Labs
|2021.2 (5.61.0.6)
|Interoperability workshop
|<span style='color:orange'>Warning</span>
|<ref name="nofiletypegetposition"/><ref name="nofiletypechunks"/>
 
|-
|'''Inductive Automation: Eclipse Milo Server SDK'''
|0.6.0
|2021-04
|OPC Labs
|2021.2 (5.61.0.6)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="filetypeonly"/>
 
|-
|'''Sterfive SAS node-opcua sdk'''
|2.27
|2021-04
|OPC Labs
|2021.2 (5.61.0.6)
|Interoperability workshop
|<span style='color:green'>Passed</span>
|<ref name="filetypeonly"/>
 
|-
|'''Unified Automation: .NET based OPC UA Server SDK'''
|3.0.9
|2021-04
|OPC Labs
|2021.2 (5.61.0.6)
|Developer test
|<span style='color:green'>Passed</span>
|<ref>BadNotImplemented moving a directory object.</ref><ref>Newly created files are referenced by HasComponent and not Organizes.</ref>
 
|}
 
 
More tests were performed, currently not explicitly listed here.

Latest revision as of 23:39, 14 March 2024

Older test lists: Application note: QuickOPC-UA Compatibility Test List

See also: QuickOPC Compatibility Test List for PubSub

Introduction

See Compatibility Test Lists - Concepts.

Platform Hardware

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
PC, Intel Core2 Quad CPU Q6600 @ 2.40 GHz 2.39 GHz; 4.00 GB 2018-06 OPC Labs 2018.2 (5.53) Basic test Passed W7SP1/x32
PC, Intel Core i7-3930K CPU @ 3.20 GHz 3.80 GHz; 32.0 GB 2015-11 OPC Labs 5.36 Interoperability workshop Passed W7SP1/x64
2016-11 OPC Labs 5.41 Interoperability workshop Passed W7SP1/x64
2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed W7SP1/x64
PC, Intel Core i7-7820X CPU @ 3.60 GHz 3.60 GHz; 32.0 GB 2018-06 OPC Labs 2018.3 (5.54) Developer test Passed W10/x64
PC, Intel Core i7-8550U CPU @ 1.80 GHz 1.99 GHz; 16.0 GB 2019-03 OPC Labs 2019.1 (5.55) Interoperability workshop Passed W10/x64
2023-03 OPC Labs 2023.1 Alpha Interoperability workshop Passed W10/x64
Raspberry Pi Model 4; 4 GB 2021-01 OPC Labs 2021.1 (5.60) Basic test Passed Raspbery Pi OS

More tests were performed, currently not explicitly listed here.

Operating Systems

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
CentOS 7.5.1804 2018-07 OPC Labs 2018.3 (5.54) Basic test Passed RID: centos.7-x64
macOS High Sierra 10.13.6 2021-02 OPC Labs 2021.1 (5.60) Basic test Passed
Microsoft Windows 7 Enterprise SP1, x64 (English) 2015-11 OPC Labs 5.36 Interoperability workshop Passed
SP1, x32 (English) 2018-06 OPC Labs 2018.2 (5.53) Basic test Passed
SP1, x64 (English) 2016-11 OPC Labs 5.41 Interoperability workshop Passed
SP1, x64 (English) 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Microsoft Windows 10 Pro 1803, x64 (English) 2018-06 OPC Labs 2018.3 (5.54) Developer test Passed RID: win10-x64
1803, x64 (English) 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
1903, x64 (English) 2019-08 OPC Labs 2019.1 (5.55.0.12) Basic test Passed
1903, x86 (English) 2019-08 OPC Labs 2019.1 (5.55.0.12) Basic test Passed
22H2, x64 (English) 2023-03 OPC Labs 2023.1 Alpha Interoperability workshop Passed
Microsoft Windows Server 2019 Datacenter 1809 (Aug 2019), x64 (English) 2019-08 OPC Labs 2019.1 (5.55.0.12) Basic test Passed
Oracle Linux 7.5 2018-07 OPC Labs 2018.3 (5.54) Basic test Passed RID: linux-x64
Raspberry Pi OS with desktop 2021-01-11 2021-01 OPC Labs 2021.1 (5.60) Basic test Passed
Red Hat Enterprise Linux 7.4 2018-06 OPC Labs 2018.3 (5.54) Basic test Passed RID: rhel.7-x64
Ubuntu 17.10 2018-06 OPC Labs 2018.3 (5.54) Basic test Passed RID: linux-x64
18.04 2018-06 OPC Labs 2018.3 (5.54) Basic test Passed RID: ubuntu.18.04-x64

More tests were performed, currently not explicitly listed here.

.NET Runtimes

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
.NET 5.0.2 2021-01 OPC Labs 2021.1 (5.60.0.13) Basic test Passed
6.0.6 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
8.0.1 2024-03 OPC Labs 2024.2 Alpha Interoperability workshop Passed
.NET Core 2.0.6 2018-06 OPC Labs 2018.3 (5.54) Basic test Passed
2.0.7 2018-06 OPC Labs 2018.3 (5.54) Basic test Passed
2.1.2 2018-07 OPC Labs 2018.3 (5.54) Basic test Passed
2.1.6 2019-07 OPC Labs 2019.1 (5.55.0.3) Interoperability workshop Passed
2.1.12 2019-08 OPC Labs 2019.1 (5.55.0.12) Basic test Passed
2.1.24 2021-01 OPC Labs 2021.1 (5.60.0.13) Basic test Passed
3.1.11 2021-01 OPC Labs 2021.1 (5.60.0.13) Basic test Passed
.NET Framework 4.7 2019-08 OPC Labs 2019.1 (5.55.0.12) Basic test Passed
4.7.2 2022-10 OPC Labs 2022.1 Alpha Basic test Passed
4.7.2 2023-03 OPC Labs 2023.1 Alpha Interoperability workshop Passed
4.8 2019-08 OPC Labs 2019.1 (5.55.0.12) Basic test Passed

More tests were performed, currently not explicitly listed here.

OPC Servers

OPC UA Generic/Data

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
- 3 -
3S-Smart Software Solutions: CODESYS OPC UA Server 2015-11 OPC Labs 5.36 Interoperability workshop Passed
V3.5.13.10 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed
3.5.19.0 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
- B -
Baker Hughes/GE: iFIX 6.0 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed
Beckhoff Automation: TF6100 OPC-UA 2.2.21 2015-11 OPC Labs 5.36 Interoperability workshop Passed
Beckhoff Automation: TwinCAT TF6100 OPC UA (Client/Server) 3.x 2016-11 OPC Labs 5.41 Interoperability workshop Passed
4.0 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Bosch Rexroth: IndraMotion MTX 14VRS 2015-11 OPC Labs 5.36 Interoperability workshop Warning [1]
- C -
Certec EDV: atvise 3.3.0 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed
- D -
dieEntwickler Elektronik: SITOP PSU8600 1.2.0-Dev 2016-11 OPC Labs 5.41 Interoperability workshop Failed [2]
- E -
Enapter GmbH: Enapter UA Server 1.00 2024-03 OPC Labs 2024.2 Alpha Interoperability workshop Passed
- F -
Fraunhofer-Gesellschaft: IOSB AAS OPC UA Server 0.3 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Fraunhofer-Gesellschaft: open62541 TestServer 1.3 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Fraunhofer-Gesellschaft: ProVis.Agent 2.15.14 2019-07 OPC Labs 2019.1 (5.55.0.3) Interoperability workshop Passed
Fraunhofer-Gesellschaft: SecurePlugAndWorkUAServer 1.1.3 2016-11 OPC Labs 5.41 Interoperability workshop Passed
- G -
General Electric Corporation: CIMPLICITY OPC UA Server 9.5 Beta 2015-11 OPC Labs 5.36 Interoperability workshop Passed [3]
General Electric Corporation: CIMPLICITY Server 9.5 SIM2 2016-11 OPC Labs 5.41 Interoperability workshop Warning [4]
- H -
Hilscher: netFIELD IoLinkMaster 8 Port V1.2.2.0 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Hilscher: OPC UA Server Micro 0.9.11.1 2016-11 OPC Labs 5.41 Interoperability workshop Warning [5]
Hilscher: OPC UA Server Nano 0.9.11.1 2016-11 OPC Labs 5.41 Interoperability workshop Warning [5]
HIMA Paul Hildebrandt: HIMA OPCUA Server 1.0 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed [6]
HMS Industrial Networks: eWON Flexy FW 13.1PR 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed
Honeywell: ControlEdge PLC R152 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
Honeywell: Experion PKS OPC UA DA/HDA Server 2020-03 OPC Labs 2020.2 (5.58.0.2) Interoperability workshop Passed [7][8]
- I -
IBHsoftec: IBH Link UA 3.07 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [9]
IBHsoftec: IBH OPC UA IOT2040 3.07 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [9]
ICONICS: GENESIS64 10.96 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Warning [10][11]
Inductive Automation: Eclipse Milo OPC-UA Server SDK 0.1.0-SNAPSHOT 2016-11 OPC Labs 5.41 Interoperability workshop Passed [12]
0.3.0-SNAPSHOT 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
1.0.0-SNAPSHOT 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Inductive Automation: Ignition OPC-UA Server 8.0 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
8.1.21-SNAPSHOT 2022-10 OPC Labs 2022.1 Alpha Basic test Passed
inray Industriesoftware GmbH: OPC Router 4 4.27.5018.76 2022-10 OPC Labs 2022.1 Alpha Basic test Passed
IPCOMM: ipConvLite 3.x 2015-11 OPC Labs 5.36 Interoperability workshop Passed
IPCOMM: ipConvOPC 3.x 2015-11 OPC Labs 5.36 Interoperability workshop Passed
- K -
Kepware Technologies: Kepware Edge[13] Beta 6.7 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
Kepware Technologies: OPC UA Server - KEPServerEX 6.0 2016-11 OPC Labs 5.41 Interoperability workshop Passed
- M -
MatrikonOPC: FLEX OPC UA SDK - Embedded Server Profile R410.3 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
MatrikonOPC: FLEX OPC UA SDK - Micro Embedded Device Server Profile R410.3 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
MatrikonOPC: FLEX OPC UA SDK - Nano Embedded Device Server Profile R410.2 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed
MatrikonOPC: FLEX OPC UA SDK - Standard Server Profile R410.3 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
Microsoft: .Net Standard Library OPC Server Nov-11-2016 2016-11 OPC Labs 5.41 Interoperability workshop Warning [14]
Microsoft: .Net Standard Reference Server (Ubuntu) Sep-18-2017 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Microsoft: .Net Standard Reference Server (Windows) 1.4.371.xx 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Microsoft: .Net Standard GDS Server Sep-18-2017 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
- O -
OMRON: NJ OPC UA Server 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [9]
- P -
Phoenix Contact: PC WORX UA Server 1.03.961.3 2015-11 OPC Labs 5.36 Interoperability workshop Warning [15]
Progea: Platform.NExT 3.3.200 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Progea: Connext 3.3.200 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Prosys OPC: OPC UA Java SDK 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Warning [16]
Prosys OPC: Sentrol - OPC UA SDK for Delphi 7.0 Beta 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Failed [17]
- R -
Real Time Automation: Royalty-Free ANSI C OPC UA Server Stack, Toolkit & SDK 1.0 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
Rockwell Automation: FactoryTalkLinxGateway 6.10 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Warning [18]
- S -
SAP SE: Plant Connectivity on Linux (Raspbian) 15.1.5 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [19]
SAP SE: Plant Connectivity on Windows 10 15.1.5 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [19]
Schneider Electric: InduSoft IoTView OPC UA Server (Linux) v8.1 SP3 2018-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
Schneider Electric: Indusoft Web Studio OPC UA Server v8.1 SP3 2018-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
Schneider Electric: M262 (n/a) 2024-03 OPC Labs 2024.2 Alpha Interoperability workshop Passed
Siemens: miniweb OPC UA 5.3.2 beta 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Failed [20]
Siemens: SIMATIC CPU 1516-3 PN/DP V2.6 2019-07 OPC Labs 2019.1 (5.55.0.3) Interoperability workshop Passed [21]
Siemens: SIMATIC NET OPC Server S7 opt V13 SP1 2015-11 OPC Labs 5.36 Interoperability workshop Warning [22]
Siemens: SIMATIC RF100 V1.1 2019-07 OPC Labs 2019.1 (5.55.0.3) Interoperability workshop Warning [23]
Siemens: SIMATIC RF600 V3.1 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed
Siemens: SIMATIC S7-1500[24] V3.0 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Siemens: SIMATIC S7-1518[24] V2.5 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Siemens: Simatic WinCC V7.4 2015-11 OPC Labs 5.36 Interoperability workshop Passed [25]
V7.5 2018-10 OPC Labs 5.54 (2018.3.0.33) Interoperability workshop Passed [25]
V8.0 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Siemens: WinCC Runtime Professional V15.1 2018-10 OPC Labs 5.54 (2018.3.0.33) Interoperability workshop Passed
Softing Industrial Automation: dataFEED OPC SIS 1.12 2019-07 OPC Labs 2019.1 (5.55.0.3) Interoperability workshop Passed
Softing Industrial Automation: dataFEED OPC Suite 4.43.0 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Warning [26]
5.22.0 2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Softing Industrial Automation: dataFEED OPC UA .NET Standard Server SDK 2.2 2019-07 OPC Labs 2019.1 (5.55.0.3) Interoperability workshop Passed
Softing Industrial Automation: edgeAggregator 3.10 2022-10 OPC Labs 2022.2 Alpha Interoperability workshop Passed
Softing Industrial Automation: Falcon Server[27] 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Warning [28]
Softing Industrial Automation: OPC UA C++ Server Development Toolkits for Windows 1.00 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Softing Industrial Automation: OPC UA Embedded Toolkit 5.53 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Softing Industrial Automation: OPC UA .NET Server Development Toolkits 1.43 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Warning [29][11]
Sterfive SAS node-opcua sdk 2.27 2021-04 OPC Labs 2021.2 (5.61.0.6) Interoperability workshop Warning [30][31]
2022-10 OPC Labs 2022.2 Alpha Basic test Passed
Systerel: S2OPC Demo Server 0.5.0* 2018-10 OPC Labs 5.54 (2018.3.0.33) Interoperability workshop Warning [32]
- T -
Takebishi: Device Gateway 2.1.2 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed
Takebishi: DeviceXPlorer OPC Server 6.0 Pre 2018-10 OPC Labs 2019.1 (5.55.0.3) Interoperability workshop Passed [33][34]
Tani: OPC Server 1.7 2015-11 OPC Labs 5.36 Interoperability workshop Passed
Tani: OPC Server Linux 1.7 2015-11 OPC Labs 5.36 Interoperability workshop Passed [35]
Tani: PLC Engine Server raspberry 1.12 2016-11 OPC Labs 5.41 Interoperability workshop Failed [2]
- U -
Unified Automation: .NET based OPC UA Server SDK 2.4.0 2015-11 OPC Labs 5.36 Interoperability workshop Warning [36][11]
Unified Automation: C based OPC UA Server SDK 1.5.1 2015-11 OPC Labs 5.36 Interoperability workshop Warning [36]
Unified Automation: C++ based OPC UA Server SDK WINDOWS 1.5.0 2015-11 OPC Labs 5.36 Interoperability workshop Warning [36]
Unified Automation: High Performance OPC UA SDK 1.3.0 BETA 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
Unified Automation: UA Gateway - connect classic OPC[37] 1.5.0 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
University of West Bohemia in Pilsen: OPC UA server for REX Control System 1.0.0 2015-11 OPC Labs 5.36 Interoperability workshop Passed
- V -
VDMA Weighing Demo Server as of test date 2021-10 OPC Labs 2021.3 Alpha Targeted test Passed [38]
- W -
WAGO Kontakttechnik: Controllers PFC100 & PFC200 0750-8212 2021-10 OPC Labs 2021.3 Alpha Interoperability workshop Passed [39][40]
- Y -
Yokogawa Electric Corporation: FAST/TOOLS OPC UA Server R10.04 SP1 2019-07 OPC Labs 2019.1 (5.55.0.3) Interoperability workshop Warning [41]
Yokogawa Electric Corporation: MDIS Demo Server 2020-03 OPC Labs 2020.2 (5.58.0.2) Interoperability workshop Passed [42]
Yokogawa Electric Corporation: opaf demo server 2019-03 OPC Labs 2019.1 (5.55.0.2) Interoperability workshop Passed
Yokogawa Electric Corporation: UA Server for CENTUM VP R1.02.10 2015-11 OPC Labs 5.36 Interoperability workshop Passed

OPC UA Global Discovery Services (GDS), Certificate Management (CM)

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
Microsoft: .Net Standard GDS server 1.5.374 2024-03 OPC Labs 2024.2 Alpha Interoperability workshop Passed
Microsoft: Azure IoT OPC Vault GDS Server private preview 2018-10 OPC Labs 2018.3 (5.54.0.33) Interoperability workshop Passed
OPC Foundation: UA .Net Standard Global Discovery Server 1.03.352.12 2018-09 OPC Labs 2018.3 (5.54.0.33) Developer Test Passed
Unified Automation: UA GDS as of test date 2021-10 OPC Labs 2021.3 Alpha Interoperability workshop Warning [43]
as of test date 2023-03 OPC Labs 2023.1 Alpha Interoperability workshop Passed

OPC UA File Transfer

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
Fraunhofer-Gesellschaft: Fraunhofer IOSB AAS OPC UA Server 0.5 2021-04 OPC Labs 2021.2 (5.61.0.6) Interoperability workshop Passed [44][45]
Hilscher: netFIELD IoLinkMaster 8 Port V1.1.7.0 2021-04 OPC Labs 2021.2 (5.61.0.6) Interoperability workshop Warning [46][47]
Hilscher: netFIELD DIOConnector 8 DIO Port V1.1.7.0 2021-04 OPC Labs 2021.2 (5.61.0.6) Interoperability workshop Warning [46][47]
Inductive Automation: Eclipse Milo Server SDK 0.6.0 2021-04 OPC Labs 2021.2 (5.61.0.6) Interoperability workshop Passed [44]
Sterfive SAS node-opcua sdk 2.27 2021-04 OPC Labs 2021.2 (5.61.0.6) Interoperability workshop Passed [44]
Unified Automation: .NET based OPC UA Server SDK 3.0.9 2021-04 OPC Labs 2021.2 (5.61.0.6) Developer test Passed [48][49]


More tests were performed, currently not explicitly listed here.

  1. do not know the HTTPS endpoint
  2. 2.0 2.1 getting BadIdentityTokenRejected from ActivateSession() with user identity = username/password
  3. the ServerDiagnostics.SessionDiagnosticsArray cannot be read with the credentials provided for testing
  4. server is revising publishing intervals to 0 and using its own
  5. 5.0 5.1 failed: reading and writing with IndexRange
  6. No dynamic nodes could have been tested.
  7. Empty ArrayDimensions instead of null returned with ValueRank=-2.
  8. DataChangeFilter=StatusValue does not prevent constant value with updating timestamps from being sent.
  9. 9.0 9.1 9.2 The SessionDiagnosticsArray node is missing, but the sessions are correctly available under SessionDiagnosticsSummary.
  10. Server sends data changes too fast.
  11. 11.0 11.1 11.2 Absolute Deadband filter: server sometimes sends notifications where the difference is less than the deadband
  12. HTTPS not supported by the server?
  13. Linux; driver-based
  14. reading Server_ServerDiagnostics_SessionsDiagnosticsSummary_SessionDiagnosticsArray (nsu=http://opcfoundation.org/UA/;i=3707) gives BadOutOfService
  15. reading ServerDiagnostics.SessionDiagnosticsArray gives BadNodeIdUnknown
  16. All nodes (even scalars from standard information model etc.) have ValueRank equal to -2 (Any): not compliant.
  17. The server returns ValuRank 0 for scalar nodes.
  18. GetEndpoints can return overloaded set of endpoints
  19. 19.0 19.1 Could not test much, server only has method calls support.
  20. 1) Effects of Writes with IndexRange are not sent through subscription. 2) Subscription ignores IndexRange. 3) After writing into an IndexRange, the whole array seems to be replaced when doing subsequent Read
  21. Sampling period 2000 ms, but receiving changes at around 1000 ms rate.
  22. Server sends changes too fast. I used sampling interval 2000 ms. The server has not revised it. But it has been sending notifications with average rate between 800-900 ms. I think it would be OK to send values faster than requested, but in that case the server should report the faster revised sampling rate properly to the client.
  23. Reading ArrayDimensions gives an array with zero elements. NodeID: ns=4;i=6013
  24. 24.0 24.1 for S7-1500 family
  25. 25.0 25.1 no arrays available for testing
  26. sometimes getting just BadWaitingForInitialData and no further update
  27. Falcon appears to be a code name for upcoming version of dataFEED OPC Suite.
  28. Getting "Could not create SSL/TLS secure channel." with HTTPS endpoint; it is possible that the problem is on the client side.
  29. Writing with index range always gives BadIndexRangeInvalid
  30. Getting BadSecurityChecksFailed with attempts to make any secure connection.
  31. Null in StructureField.DataType (AutoID ScanData) instead of BaseDataType.
  32. There are nodes that have variable class, but return BadAttributeInvalid for the UserAccessLevel and Historizing attributes, which are mandatory.
  33. When the publishing rate was 1000 ms and sampling rate 2000 ms, the server provides changes every 1000 ms, which means it is sampling faster than requested.
  34. On subsequent connections after a network interruption, no initial update was sent for items that are static.
  35. values not changing
  36. 36.0 36.1 36.2 looks like LDS is not running
  37. based on Unified Automation C++ SDK
  38. Reading weight structures, such as nsu=http://yourorganisation.org/isw_personwaage/ ;ns=4;i=6001 .
  39. Structure fields that are multi-dimensional arrays are encoded incorrectly: The array of actual dimensions is missing, and instead, just the total number of elements is encoded, as if the array was one-dimensional.
  40. StructureField.maxStringLength is in characters and not in UTF-8 encoded bytes.
  41. Buggy NodeClassMask filtering in Browse service.
  42. Sample delivery approx. 50% slower than requested.
  43. PFX format not supported (only PEM) in StartNewKeyPairRequest. Consequently, QuickOPC needs to target .NET Standard so that it can use StartSigningRequest instead.
  44. 44.0 44.1 44.2 Only isolated files available for test (no directores/file system).
  45. File writing was not available for test.
  46. 46.0 46.1 GetPosition method of FileType does not work.
  47. 47.0 47.1 File must be written using a single call to the Write method on FileType (no chunking possible).
  48. BadNotImplemented moving a directory object.
  49. Newly created files are referenced by HasComponent and not Organizes.