Using OpcCmd Utility as OPC UA Server: Difference between revisions
From OPC Labs Knowledge Base
Line 6: | Line 6: | ||
== Command: uaServer start == | == Command: uaServer start == | ||
This command starts an OPC UA server with pre-defined content (data variables | This command starts an OPC UA server with pre-defined content (data variables with various behavior and data types under the standard '''Objects''' folder). By default, it opens its endpoint on "opc.tcp://localhost:48040/". | ||
== Command: uaServer addMesh == | == Command: uaServer addMesh == |
Revision as of 12:47, 25 February 2025
For general information about the OpcCmd tool, see Category:OpcCmd Utility.
Commands, Arguments and Options
Command: uaServer start
This command starts an OPC UA server with pre-defined content (data variables with various behavior and data types under the standard Objects folder). By default, it opens its endpoint on "opc.tcp://localhost:48040/".
Command: uaServer addMesh
This command adds nodes to the OPC UA server address space mesh. You need to specify the mesh name, and optionally a mesh-specific parameter. Currently, only one mesh is available, named PredefinedNodes. The optional parameter is an integer specifying the count of shared counter nodes (defaults to 10000).
The mesh(es) need to be added before you start the server.
Example:
uaServer addMesh PredefinedNodes 20000