Difference between revisions of "Error "The specified network password is not correct." or "The requested key container was not found.""

From OPC Labs Knowledge Base
Jump to navigation Jump to search
Line 1: Line 1:
 
[[Category:Troubleshooting]]
 
[[Category:Troubleshooting]]
 +
= Symptoms =
 +
 +
= Resolution =
  
 
#In Windows File Explorer, navigate to C:\ProgramData\Microsoft\Crypto\RSA .
 
#In Windows File Explorer, navigate to C:\ProgramData\Microsoft\Crypto\RSA .
Line 12: Line 15:
 
#Press OK to close the Advanced Security Settings for MachineKeys (Erweiterte Sicherheitseinstellungen für "MachineKeys")  dialog.
 
#Press OK to close the Advanced Security Settings for MachineKeys (Erweiterte Sicherheitseinstellungen für "MachineKeys")  dialog.
 
#Press OK to close the MachineKeys Properties (Eigenschaften von MachineKeys) dialog.
 
#Press OK to close the MachineKeys Properties (Eigenschaften von MachineKeys) dialog.
 +
 +
= More information =
 +
 +
= See also =

Revision as of 05:17, 16 June 2021

Symptoms

Resolution

  1. In Windows File Explorer, navigate to C:\ProgramData\Microsoft\Crypto\RSA .
  2. Right-click on the MachineKeys folder, and select the Properties (Eigenschaften) command.
  3. In the MachineKeys Properties (Eigenschaften von MachineKeys) dialog, switch to the Security (Sicherheit) tab.
  4. Press the Advanced (Erweitert) button.
  5. In the Advanced Security Settings for MachineKeys (Erweiterte Sicherheitseinstellungen für "MachineKeys") dialog, press the Change permissions (Berechtigungen ändern) button.
  6. Press the Disable inheritance (Vererbung deaktivieren) button, and confirm the default selection, which is to convert the inherited permissions into explicit permissions.
  7. Back in the Advanced Security Settings for MachineKeys (Erweiterte Sicherheitseinstellungen für "MachineKeys") dialog, select the row with permission entries for Everyone (Jeder), and press the Edit (Bearbeiten) button.
  8. In the Permission Entry for MachineKeys (Berechtigungseintrag für "MachineKeys") dialog, under the Basic permissions (Grundlegende Berechtigungen), enable the checkbox next to the Write (Schreiben) permission.
  9. Press OK to close the Permission Entry for MachineKeys (Berechtigungseintrag für "MachineKeys") dialog.
  10. Press OK to close the Advanced Security Settings for MachineKeys (Erweiterte Sicherheitseinstellungen für "MachineKeys") dialog.
  11. Press OK to close the MachineKeys Properties (Eigenschaften von MachineKeys) dialog.