QuickOPC Compatibility Test List

From OPC Labs Knowledge Base
Jump to navigation Jump to search

Older test lists: Application note: QuickOPC-UA Compatibility Test List

Introduction

The Compatibility Test List documents the test performed with the product with the aim to assure its compatibility widest range of systems it depends on or interoperates with. This document is updated from time to time, as new tests are being performed.

This document is grouped by the classes of systems that this product depends on or interoperates with, such as "Platform hardware" or "Operating systems". Each class has a standalone chapter.

The entries in each group are sorted by the columns from left to right, i.e. first by "Other system model", then by "Other system version", and then by "Test date.

Field descriptions

Other system model

"Other system" is the system we are testing the compatibility of this product with. It can be hardware, software, or a combination.

Other system version

This field contains additional details about the other system, typically its versioning information, if available.

Test date

Describes when the test was performed. It can be a specific date, date range, or approximate date such as a month in a year.

Performed by

This field determines the entity (person or organization) that has performed the test.

This product version

This field contains versioning information about this (our) product, typically including the software build and revision numbers, too.

If a test that was otherwise identical in other parameters has been performed with a newer version of this product, and the outcome was the same or better, the old entry in the compatibility test list may be removed for brevity. This is done so because the main purpose of the compatibility test list is to assess the compatibility of the latest available version of this product.

On the other hand, entries for tests performed with earlier versions of this product that were not repeated later are always retained. It can be assumed that later versions of this product continue to operate with at least the same outcome as the version that has been tested.

Test type

  • Alpha test.
  • Basic test.
  • Compliance test.
  • Developer test.
  • Field test.
  • Interoperability workshop.

Test outcome

  • Failed. There is always a Note describing the details.
  • Inconclusive. There is always a Note describing the details.
  • Passed.
  • Warning. There is always a Note describing the details.

Notes

This field contains any relevant notes, especially to the test environment, or outcome of the test.

Platform hardware

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
Intel Core i7-3930K CPU @ 3.20 GHz 3.80 GHz; 32.0 GB 2015-11 OPC Labs 5.36 Interoperability workshop Passed W7SP1/x64
Intel Core i7-3930K CPU @ 3.20 GHz 3.80 GHz; 32.0 GB 2016-11 OPC Labs 5.41 Interoperability workshop Passed W7SP1/x64
Intel Core i7-3930K CPU @ 3.20 GHz 3.80 GHz; 32.0 GB 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed W7SP1/x64

More tests were performed, currently not explicitly listed here.

Operating systems

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
Microsoft Windows 7 Enterprise SP1 x64 (English) 2015-11 OPC Labs 5.36 Interoperability workshop Passed
Microsoft Windows 7 Enterprise SP1 x64 (English) 2016-11 OPC Labs 5.41 Interoperability workshop Passed
Microsoft Windows 7 Enterprise SP1 x64 (English) 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed

More tests were performed, currently not explicitly listed here.

.NET runtimes

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
.NET Core 2.0.6 2018-06 OPC Labs 5.54 Basic test Passed
.NET Core 2.0.7 2018-06 OPC Labs 5.54 Basic test Passed

OPC servers

Other system model Other system version Test date Performed by This product version Test type Test outcome Notes
3S-Smart Software Solutions: CODESYS OPC UA Server 2015-11 OPC Labs 5.36 Interoperability workshop Passed
Beckhoff Automation: TF6100 OPC-UA 2.2.21 2015-11 OPC Labs 5.36 Interoperability workshop Passed
Beckhoff Automation: TwinCAT TF6100 OPC UA (Client/Server) 3.x 2016-11 OPC Labs 5.41 Interoperability workshop Passed
Bosch Rexroth: IndraMotion MTX 14VRS 2015-11 OPC Labs 5.36 Interoperability workshop Warning [1]
dieEntwickler Elektronik: SITOP PSU8600 1.2.0-Dev 2016-11 OPC Labs 5.41 Interoperability workshop Failed [2]
Fraunhofer-Gesellschaft: SecurePlugAndWorkUAServer 1.1.3 2016-11 OPC Labs 5.41 Interoperability workshop Passed
General Electric Corporation: CIMPLICITY OPC UA Server 9.5 Beta 2015-11 OPC Labs 5.36 Interoperability workshop Passed [3]
General Electric Corporation: CIMPLICITY Server 9.5 SIM2 2016-11 OPC Labs 5.41 Interoperability workshop Warning [4]
Hilscher: OPC UA Server Micro 0.9.11.1 2016-11 OPC Labs 5.41 Interoperability workshop Warning [5]
Hilscher: OPC UA Server Nano 0.9.11.1 2016-11 OPC Labs 5.41 Interoperability workshop Warning [5]
IBHsoftec: IBH Link UA 3.07 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [6]
IBHsoftec: IBH OPC UA IOT2040 3.07 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [6]
Inductive Automation: Eclipse Milo OPC-UA Server SDK 0.1.0-SNAPSHOT 2016-11 OPC Labs 5.41 Interoperability workshop Passed [7]
IPCOMM: ipConvLite 3.x 2015-11 OPC Labs 5.36 Interoperability workshop Passed
IPCOMM: ipConvOPC 3.x 2015-11 OPC Labs 5.36 Interoperability workshop Passed
Kepware Technologies: OPC UA Server - KEPServerEX 6.0 2016-11 OPC Labs 5.41 Interoperability workshop Passed
Microsoft: .Net Standard Library OPC Server Nov-11-2016 2016-11 OPC Labs 5.41 Interoperability workshop Warning [8]
Microsoft: .Net Standard Reference Server (Ubuntu) Sep-18-2017 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Microsoft: .Net Standard GDS Server Sep-18-2017 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
OMRON: NJ OPC UA Server 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [6]
Progea: Platform.NExT 3.3.200 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Progea: Connext 3.3.200 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Phoenix Contact: PC WORX UA Server 1.03.961.3 2015-11 OPC Labs 5.36 Interoperability workshop Warning [9]
Prosys OPC: OPC UA Java SDK 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Warning [10]
SAP SE: Plant Connectivity on Linux (Raspbian) 15.1.5 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [11]
SAP SE: Plant Connectivity on Windows 10 15.1.5 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [11]
Siemens: miniweb OPC UA 5.3.2 beta 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Failed [12]
Siemens: SIMATIC NET OPC Server S7 opt V13 SP1 2015-11 OPC Labs 5.36 Interoperability workshop Warning [13]
Siemens: SIMATIC NET OPC Server S7 opt V13 SP1 2015-11 OPC Labs 5.36 Interoperability workshop Warning [13]
Siemens: SIMATIC S7-1518 V2.5 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed [14]
Siemens: Simatic WinCC V7.4 2015-11 OPC Labs 5.36 Interoperability workshop Passed [15]
Softing Industrial Automation: dataFEED OPC Suite 4.43.0 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Warning [16]
Softing Industrial Automation: Falcon Server 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Warning [17][18]
Softing Industrial Automation: OPC UA C++ Server Development Toolkits for Windows 1.00 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Softing Industrial Automation: OPC UA Embedded Toolkit 5.53 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Passed
Softing Industrial Automation: OPC UA .NET Server Development Toolkits 1.43 2017-09 OPC Labs 2017.2 (5.51.0.7) Interoperability workshop Warning [19][20]
Tani: OPC Server 1.7 2015-11 OPC Labs 5.36 Interoperability workshop Passed
Tani: OPC Server Linux 1.7 2015-11 OPC Labs 5.36 Interoperability workshop Passed [21]
Tani: PLC Engine Server raspberry 1.12 2016-11 OPC Labs 5.41 Interoperability workshop Failed [2]
Unified Automation: C based OPC UA Server SDK 1.5.1 2015-11 OPC Labs 5.36 Interoperability workshop Warning [22]
Unified Automation: C++ based OPC UA Server SDK WINDOWS 1.5.0 2015-11 OPC Labs 5.36 Interoperability workshop Warning [22]
Unified Automation: .NET based OPC UA Server SDK 2.4.0 2015-11 OPC Labs 5.36 Interoperability workshop Warning [22][20]
University of West Bohemia in Pilsen: OPC UA server for REX Control System 1.0.0 2015-11 OPC Labs 5.36 Interoperability workshop Passed
Yokogawa Electric Corporation: UA Server for CENTUM VP R1.02.10 2015-11 OPC Labs 5.36 Interoperability workshop Passed

More tests were performed, currently not explicitly listed here.

  1. do not know the HTTPS endpoint
  2. 2.0 2.1 getting BadIdentityTokenRejected from ActivateSession() with user identity = username/password
  3. the ServerDiagnostics.SessionDiagnosticsArray cannot be read with the credentials provided for testing
  4. server is revising publishing intervals to 0 and using its own
  5. 5.0 5.1 failed: reading and writing with IndexRange
  6. 6.0 6.1 6.2 The SessionDiagnosticsArray node is missing, but the sessions are correctly available under SessionDiagnosticsSummary.
  7. HTTPS not supported by the server?
  8. reading Server_ServerDiagnostics_SessionsDiagnosticsSummary_SessionDiagnosticsArray (nsu=http://opcfoundation.org/UA/;i=3707) gives BadOutOfService
  9. reading ServerDiagnostics.SessionDiagnosticsArray gives BadNodeIdUnknown
  10. All nodes (even scalars from standard information model etc.) have ValueRank equal to -2 (Any): not compliant.
  11. 11.0 11.1 Could not test much, server only has method calls support.
  12. 1) Effects of Writes with IndexRange are not sent through subscription. 2) Subscription ignores IndexRange. 3) After writing into an IndexRange, the whole array seems to be replaced when doing subsequent Read
  13. 13.0 13.1 Server sends changes too fast. I used sampling interval 2000 ms. The server has not revised it. But it has been sending notifications with average rate between 800-900 ms. I think it would be OK to send values faster than requested, but in that case the server should report the faster revised sampling rate properly to the client.
  14. for S7-1500 family
  15. no arrays available for testing
  16. sometimes getting just BadWaitingForInitialData and no further update
  17. Falcon appears to be a code name for upcoming version of dataFEED OPC Suite.
  18. Getting "Could not create SSL/TLS secure channel." with HTTPS endpoint; it is possible that the problem is on the client side.
  19. Writing with index range always gives BadIndexRangeInvalid
  20. 20.0 20.1 Absolute Deadband filter: server sometimes sends notifications where the difference is less than the deadband
  21. values not changing
  22. 22.0 22.1 22.2 looks like LDS is not running